Description: Original FLUKE 18B+ Digital MultiMeter with FREE carrying bag Origin China Attention notice Our aim is to make you happy and satisfy in our store totally, providing the best product and best service. However, there still some problem happen. Items may be broken during the shipping way or item can not work or compatible with your items suitable. If such anything or any problem happened, please send a message to us by ebay or our email. Firstly and directly, before leaving any feedback or open any dispute. Please give us the opportunity to resolve the problem. We must guarantee you 100% satisfaction in our store. If you want buy much quantity or any other type item you like, please contact us by our email, or ebay message we can supply you, and give you much more discount, the super quality and service. Tks! 100% Brand New include battery. Feature: LED backlight (new) MIN/MAX Mode (new) Larger screen: 1.5 times of F18B's (new) Faster response time than F18B (new) Date Hold Function Both Auto range and Manual range Selectable Over range protection for all ranges Polarity Indication: Indicates negative polarity Overflow Indication Sleep Mode /Auto Power off / Low Battery Indication Continuity Test with Alert Diode Test Power Supply: 2 x AA 1.5V Battery General Specifications: Maximum Voltage between any Terminal and Earth Ground: 1000 V Display(LCD)......................................................4000 counts,updates 3/sec Battery Type.......................................................2 AA,NEDA 15A, IEC LR6 Battery life..........................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test) Temperatuer Operating............................................................0 deg to 40 deg Storage...............................................................-30 deg to 60 deg Relative Humidity Operating Humidity...........................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg Operating Humidity,40MC Range....................≤80% at 10deg to 30deg;≤70% at 30deg to 40deg Altitude Operating............................................................2000m Storage...............................................................12.000m Temperature Coefficient...................................0.1×(specified accuracy)/deg(<18deg or > 28deg) Fuse protection for current inputs...................440 mA,1000 V Fast Fuse, Fluck specified part only. 11A,1000v Fast Fuse, Fluke specified part only. Size(H×W×L)......................................................183×91×49.5(mm) Weight.................................................................455g IP Rating.............................................................IP 40 Safety..................................................................IEC 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2 Electromagnetic Environment..........................IEC 61326-1:Portable E lectromagnetic Compatibility.........................Applies to use in Korea only Class A Equipment(Industrial Broadcasting and Communication Equipment) ACCURACY SPECIFICATION Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) AC and DC Voltage Function Range Resolution Accuracy 15B+ 17B+ 18B+ AC Volts (40Hz-500Hz)[1] 4.000V 40.00V 400.0V 1000V 0.001V 0.01V 0.1V 1V 1.0 % + 3 1.0 % + 3 1.0 % + 3 AC Millivolts 400.0mV 0.1mV 3.0 % + 3 3.0 % + 3 3.0 % + 3 DC Millivolts 400.0mV 0.1mV 1.0 % + 10 1.0 % + 10 1.0 % + 10 DC volts 4.000V 40.00V 400.0V 1000V 0.001V 0.01V 0.1V 1V 0.5 % + 3 0.5 % + 3 0.5 % + 3 [1]All ac, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. AC and DC current Function Range Resolution Accuracy 15B+ 17B+ 18B+ AC Current μA (40 Hz-400Hz) 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3 1.5 % + 3 1.5 % + 3 AC current Ma (40Hz – 400Hz) 40.00 m 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3 1.5 % + 3 1.5 % + 3 AC current A[1] (40Hz – 400Hz) 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 1.5 % + 3 1.5 % + 3 DC current μA 400.0 μA 4000 μA 0.1 μA 1 μA 1.5 % + 3 1.5 % + 3 1.5 % + 3 DC current mA 40.00 mA 400.0 mA 0.01 mA 0.1 mA 1.5 % + 3 1.5 % + 3 1.5 % + 3 DC current A[1] 4.000 A 10.00 A 0.001 A 0.01 A 1.5 % + 3 1.5 % + 3 1.5 % + 3 [1] 10 A duty cycle < minutes on, 20 minutes off. Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle Function Range Resolution Accuracy 15B+ 17B+ 18B+ Diode Test[1] 2.000V 0.001V 10 % Temperature 50.0°C-400.0°C 0°C-50.0°C -55.0°C -0°C 0.1°C NA 2 % +1°C 2°C 9% +2°C NA Resistance (Ohms) 400.0Ω 4.000KΩ 40.00KΩ 400.0KΩ 4.000MΩ 40.00MΩ 0.1Ω 0.001KΩ 0.01KΩ 0.1KΩ 0.001MΩ 0.01MΩ 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 0.5%+3 0.5%+2 0.5%+2 0.5%+2 0.5%+2 1.5%+3 Capacitance[2] 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 1000 μF 0.01 nF 0.1 nF 0.001μF 0.01μF 0.1μF 1μF 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 2% + 5 2% + 5 5% + 5 5% + 5 5% + 5 5% + 5 Frequency[3] (10Hz -100kHz) Hz 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz NA 0.1%+3 0.1%+3 Duty Cycle[2] 1% to 99% 0.1 % NA 1%typical[4] 1% typical[4] [1] Typically, open circuit test voltage is 2.0 V and short circuit is <0.6 mA [2] Specifications do not include errors due to test lead capacitance and capacitance floor(may be up to 1.5nF in the 40 nF range). [3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. In puts below 1 % of range are not specified. [4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90 %. LED Test and Continuity Threshold Function Lighting Range Measurement Range Resolution Accuracy LED VF Test[1] (LED Test Socket) 1.00 to 6.00 V NA NA NA LED VF Test[2] ( Test leads) 1.00 to 6.00V 1.00 to 6.00V 0.01V 10%[3] Continuity Threshold NA NA NA NA [1] Open circuit test voltage is±12V and short-circuit current is<±5mA(typical) [2] Open circuit test voltage is±12V and short-circuit current is<±3mA(typical) [3] VF Measurement with driving current under2.2±0.4 mA Input Characteristics Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio AC Volts 1000V[1] >10MΩ,
Price: 159.9 USD
Location: Dayton, New Jersey
End Time: 2024-12-30T10:43:57.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Fluke
Type: Multimeter
Model: 18B+
MPN: F18B+
Display: Digital